Home About Services RelaNex Academy Why Us Contact Get in Touch →
ENRUAZ

Protection Incident Analysis

We investigate unwanted trips and failures to operate through detailed analysis of disturbance records, sequence-of-events logs, relay settings and protection logic. Our assessment reconstructs the incident, evaluates protection performance against the intended operating philosophy, and identifies probable causes and contributing factors.

Typical reasons for investigation

  • Unwanted or unexplained trips.
  • Failure to trip during an expected protection condition.
  • Unexpected operation sequences.
  • Suspected coordination or logic problems.
  • Repeated incidents following system changes.

Information we may require

  • Disturbance records, including COMTRADE files where available.
  • Relay event logs and settings.
  • Configuration files and logic diagrams.
  • Relevant schematics and single-line diagrams.
  • Equipment data and operating conditions.
  • Available breaker, SCADA or other event records.

What you receive

A documented incident-analysis report setting out the event chronology, reviewed evidence, assessment of protection behavior, probable causes, uncertainties and recommended corrective actions.

  • Event chronology reconstructed from disturbance records, event logs and other available records.
  • Assessment of relay and scheme behavior against the settings, logic and intended protection philosophy.
  • Probable causes and contributing factors, each with its supporting evidence.
  • Recommended corrective actions and any further checks or tests needed.

Findings depend on the quality and completeness of available records. Where evidence is insufficient, we identify uncertainties and the additional information or testing needed.

Site inspections, testing, configuration changes and implementation of corrective actions are included only where separately agreed.

Related services

Relay Settings Calculations & Coordination

Setting calculations and coordination studies assessing sensitivity, selectivity and operating times.

Relay Configuration & Protection Logic Development

Device-specific relay configurations, programmable logic and signal assignments, developed in the manufacturer's engineering tools.

Protection & Control Reverse Engineering

Reconstruction of existing protection and control arrangements where records are missing, incomplete or outdated.

All RelaNex Group services →

Need a protection incident investigated?

Work directly with the engineers doing the analysis — clear scoping from the first conversation.

Get in Touch